Methodology of testing guided-type fall arresters with rail-based rigid anchor lines

Main Article Content

Milan Bižić
Dragan Petrović

Abstract

Guided-type fall arresters with a rigid anchor line made of rail are among the most effective ways of fall protection from height. Their primary role is to ensure the user’s safe movement during climbing and to protect them in the event of a sudden fall. Given that the functionality and reliability of this personal fall protection equipment directly impact the user's safety, the requirements for its quality are very rigorous. These requirements are precisely defined in European standards. Therefore, the aim of this paper is to provide a systematic overview of the methodology of testing of guided-type fall arresters with a rigid anchor line made of rail, in accordance with standard EN 353-1. This methodology is developed by the Laboratory for Railway Engineering and Structures Testing at the Faculty of Mechanical and Civil Engineering in Kraljevo, University of Kragujevac, Serbia. The paper analyzes the requirements for the physical, geometric, and mechanical characteristics of guided-type fall arresters and rigid anchor lines made of rail. Special attention is given to the procedures for performing both static and dynamic tests. The results of the conducted research provide a basis for assessing the potential for developing and manufacturing this type of personal fall protection equipment for the international market, while also contributing to ongoing efforts to improve its quality and safety by offering insights relevant to global production and certification processes

Article Details

How to Cite
[1]
M. Bižić and D. Petrović, “Methodology of testing guided-type fall arresters with rail-based rigid anchor lines ”, ET, vol. 4, no. 1, pp. 31–40, May 2025.
Section
Original Scientific Papers

References

[1] Y. Kang, S. Siddiqui, S. J. Suk, S. Chi, and C. Kim, “Trends of fall accidents in the U.S. construction industry”, Journal of Construction Engineering and Management, Vol. 143(8), pp. 04017043-1–04017043-7, https://doi.org/10.1061/(ASCE)CO.1943-7862.0001332, (2017)

[2] X. S. Dong, A. Fujimoto, K. Ringen, and Y. Men, “Fatal falls among Hispanic construction workers”, Accident Analysis & Prevention, Vol. 41(5), pp. 1047–1052, https://doi.org/10.1016/j.aap.2009.06.012, (2009)

[3] J. E. Beavers, J. R. Moore, and W. R. Schriver, “Steel erection fatalities in the construction industry”, Journal of Constrution Engineering and Management, Vol. 135(3), pp. 227–234, https://doi.org/10.1061/(ASCE)0733-9364(2009)135:3(227), (2009)

[4] A.S. Chan, F. K. W. Wong, D. W. M. Chan, M. C. H. Yam, A. W. K. Kwok, E. W. M. Lam, and E. Cheung, “Work at height fatalities in the repair, maintenance, alteration, and addition works”, Journal of Construction Engineering and Management, Vol. 134(7), pp. 527–535, https://doi.org/10.1061/(ASCE)0733-9364(2008)134:7(527), (2008)

[5] N. T. Pham, G. Lelikov, and D. Korolchenko, “Improvement of the safety systems for working at heights on transmission towers”, IOP Conf. Ser. Mater. Sci. Eng., Vol. 365(4), p. 042054, https://doi.org/10.1088/1757-899X/365/4/042054, (2018)

[6] Personal fall protection equipment – Guided type fall arresters including an anchor line – Part 1: Guided type fall arresters including a rigid anchor line”, Standard SRPS EN 353-1:2018, (2018)

[7] C. C. Liang and C. F. Chiang, “A study on biodynamic models of seated human subjects exposed to vertical vibration”, International Journal of Industrial Ergonomics, Vol. 36(10), pp. 869–890, https://doi.org/10.1016/j.ergon.2006.06.008, (2006)

[8] J. B. Hernández, M. B. Hernández, G.R. Ortega, F. J. S. Ruiz, V. F. Lara, C. A. M. Santos, “Energy dissipating component in fall arrest system”, South Florida Journal of Development, Vol. 5(12), pp. 01-15, https://doi.org/10.46932/sfjdv5n12-061, (2024)

[9] K. Baszczyński, “Influence of weather conditions on the performance of energy absorbers and guided type fall arresters on a flexible anchorage line during fall arresting”, Safety Science, Vol. 42(6), pp. 519-536, https://doi.org/10.1016/j.ssci.2003.08.003, (2004)

[10] K. Baszczyński, “The influence of anchor devices on the performance of retractable type fall arresters protecting against falls from a height”, International Journal of Occupational Safety and Ergonomics, Vol. 12(3), pp. 307-318, https://doi.org/10.1080/10803548.2006.11076692, (2015).

[11] Y. M. Goh, P. E. D. Love, “Adequacy of personal fall arrest energy absorbers in relation to heavy workers”, Safety Scence, Vol. 48(6), pp. 747-754, https://doi.org/10.1016/j.ssci.2010.02.020, (2010)

[12] Y. M. Goh, “Empirical investigation of the average deployment force of personal fall-arrest energy absorbers”, Journal of Construction Engineering and Management, Vol. 141(1), pp. 04014059-1–04014059-6, https://doi.org/10.1061/(ASCE)CO.1943-7862.0000910, (2015)

[13] https://www.vertiqualsafety.com/en/fall-arresters/fall-arresters-on-rigid-line-en-353-1/twinstop-1

[14] Personal protective equipment against falls from a height – Full body harnesses, Standard SRPS EN 361:2007, (2007)

[15] Personal protective equipment against falls from a height – Connectors, Standard SRPS EN 362:2008, (2008)

[16] Personal protective equipment against falls from a height – Test methods, Standard SRPS EN 364:2007, (2007)

[17] Corrosion tests in artificial atmospheres – Salt spray tests, Standard SRPS EN ISO 9227:2023, (2023)